1. Physical Dimensions & Cabinet Cutout Aperture
| Wall / Cabinet Cutout Width | 240 mm |
|---|---|
| Wall / Cabinet Cutout Height | 240 mm |
| Minimum Required Depth | 440 mm |
| Capacity / Output Specification | 9.0 Litres (2 Gallons) |
2. Power, Energy & Operating Ratings
| Fuel / Power Sources | Dual Fuel: LPG Gas & 240V Mains Immersion Element |
|---|---|
| Voltage & Element Rating | 240V AC Immersion (660W) / 12V DC Controller |
| LPG Operating Gas Pressure | 28 mbar Butane / 37 mbar Propane |
| Direct Interchangeability | Henry Water Heater, Truma Ultrastore (requires exterior flue adaptor plate). |
3. Known Common Faults & Diagnostic Guidance
Common UK In-Service Failure Points:
Frost-cracked cast aluminium tank casting, seized nylon drain plug, failed remote wall control switch PCB, burn-out of 660W immersion element.
Frost-cracked cast aluminium tank casting, seized nylon drain plug, failed remote wall control switch PCB, burn-out of 660W immersion element.
4. Scotia Yard Teardown & Bench-Testing Standards
Pre-Sale Salvage Verification Procedure:
Pressure test aluminium tank for hairline winter frost splits; verify non-return valve condition; inspect tie rod thread.
Pressure test aluminium tank for hairline winter frost splits; verify non-return valve condition; inspect tie rod thread.