1. Physical Dimensions & Cabinet Cutout Aperture

Wall / Cabinet Cutout Width395 mm
Wall / Cabinet Cutout Height470 mm
Minimum Required Depth130 mm
Capacity / Output Specification1.8 kW heat output

2. Power, Energy & Operating Ratings

Fuel / Power SourcesLPG Gas Radiant Convector
Voltage & Element RatingNone (mechanical Piezo ignition) or 1.5V AA battery box
LPG Operating Gas Pressure28 mbar Butane / 37 mbar Propane
Direct InterchangeabilityTrumatic S2200 (with cabinet trim adjustments).

3. Known Common Faults & Diagnostic Guidance

Common UK In-Service Failure Points:
Blocked pilot jet, glass inspection sight window cracked, thermocouple thermal decay.

4. Scotia Yard Teardown & Bench-Testing Standards

Pre-Sale Salvage Verification Procedure:
Verify front brown/cream enamel fire front is unbent; check flue chimney connector flange for rust.