1. Physical Dimensions & Cabinet Cutout Aperture
| Wall / Cabinet Cutout Width | 260 mm |
|---|---|
| Wall / Cabinet Cutout Height | 260 mm |
| Minimum Required Depth | 350 mm |
| Capacity / Output Specification | 10 Litres stainless steel tank |
2. Power, Energy & Operating Ratings
| Fuel / Power Sources | Dual Fuel: LPG Gas & 230V Electric Element (850W / 1300W) |
|---|---|
| Voltage & Element Rating | 230V (850W/1300W) / 12V control circuit |
| LPG Operating Gas Pressure | 30 mbar Bulkhead / 28 mbar Cylinder |
| Direct Interchangeability | Truma Ultrastore Series 3, Truma B10/B14. |
3. Known Common Faults & Diagnostic Guidance
Common UK In-Service Failure Points:
Split plastic cowl cowl lugs, red-light lockout on rotary wall switch, frost-damaged yellow drain valve (FrostControl).
Split plastic cowl cowl lugs, red-light lockout on rotary wall switch, frost-damaged yellow drain valve (FrostControl).
4. Scotia Yard Teardown & Bench-Testing Standards
Pre-Sale Salvage Verification Procedure:
Inspect stainless vessel welds for frost bulging; test heating element resistance; test 12V solenoid gas valve click.
Inspect stainless vessel welds for frost bulging; test heating element resistance; test 12V solenoid gas valve click.
Need Spares, Burners, Elements or a Replacement Ultrastore 10L Rapid (Series 1 & 2)?
Scotia Caravan & Motorhome Salvage tests and stocks second-hand OEM fridges, water heaters, and fires at our Inverurie depot.