1. Physical Dimensions & Cabinet Cutout Aperture
| Wall / Cabinet Cutout Width | 480 mm |
|---|---|
| Wall / Cabinet Cutout Height | 505 mm |
| Minimum Required Depth | 195 mm |
| Capacity / Output Specification | 3.4 kW heat output |
2. Power, Energy & Operating Ratings
| Fuel / Power Sources | Gas convector (optional Truma Ultraheat 230V electric pack) |
|---|---|
| Voltage & Element Rating | 1.5V battery igniter (or 230V / 12V with Ultraheat & Trumavent) |
| LPG Operating Gas Pressure | 30 mbar / 28 mbar |
| Direct Interchangeability | Carver 3600STC, Truma S3004. |
3. Known Common Faults & Diagnostic Guidance
Common UK In-Service Failure Points:
Battery igniter box corrosion from leaking batteries, Ultraheat heating relay click failure on control board.
Battery igniter box corrosion from leaking batteries, Ultraheat heating relay click failure on control board.
4. Scotia Yard Teardown & Bench-Testing Standards
Pre-Sale Salvage Verification Procedure:
Remove front case; verify cast heat exchanger is intact with no cracks; test igniter spark pulse.
Remove front case; verify cast heat exchanger is intact with no cracks; test igniter spark pulse.
Need Spares, Burners, Elements or a Replacement Trumatic S 3002 / S 3002 P?
Scotia Caravan & Motorhome Salvage tests and stocks second-hand OEM fridges, water heaters, and fires at our Inverurie depot.